PDFPrintE-mail
COMBUSTION CHECK GAS ANALYZEREurotron-Compact Combustion Analyser-GCC

Eurotron-Basic Combustion Analyzer-GBC

( Eurotron )

General

Easy replaceable gas sensors UniGas 1000 uses long life low maintenance sensors for O and CO. 2 Standard Report of Calibration Rechargeable battery operations Each instrument is factory calibrated and certified against Eurotron Standard to ensure traceability, and shipped with a Report of Calibration. Ni-MH rechargeable batteries provide longer field use. Flue gas analyser and internal printer is powered by unique batteries. Charger is supplied as standard.

 

Built-in impact printer The instrument is available with or without a built-in rugged impact printer. It uses a low cost common roll of paper as pipework leak with pressure decay programme Certainly more readable, long time and heat resistant than the thermal printout on chemical paper Pressure/Draft input Differential pressure input to verify:  draft, g , gas flow pressure, pressure in combustion chamber, P on filters and fan,

pressure switches calibration.

 

Smoke index Smoke index measurement is performed by using the optional external hand pump. The results can be stored in the internal memory and printed on the report. Ambient CO safety monitoring A procedure can be selected to monitor the CO in ambient air using the internal sensors. An internal program allows the CO max measurement in atmospheric boiler check.

 

Compact and Ergonomic

Fits in Your Hand

Easy to Use with Large Multiline Display

Automatic LCD Backlight

Built-in Impact Printer

CO with 1 ppm Resolution

180mm or 300mm Removable Flue Gas Probe

Proprietary Design Water Trap

Draft & Differential Pressure Meter

Ambient CO Monitoring

Rechargeable Battery

Real Time Clock

IR Output to Use Your Thermal Printer

 

Specifications:

Calibration

automatic calibration procedure at instrument switch-On

Self-diagnosis

Sensors efficiency test with display diagnostic messages

Fuel types

Up to 10 selectable from keyboard.

Power supply

High capacity Ni- MH rechargeable battery pack / external battery charger.

Charging time

8h at 90% with instrument Off.

Battery life

6 hours (typical) continuous use (without printing  and backlight).

Printer power supply

from the analyser battery pack.

Printed report header

4 programmable lines.

Display

40x58 mm alpha-numeric LCD with backlight device.

Infrared port

compatible with HP82240B cordless printer

Operating temperature

from -5°C to +45°C

Storage temperature

from -20 to +60°C (3 months maximum at temperatures exceeding the

operational limits).

Dimensions and Weight

115x90x330 mm - 1.1 kg with battery and printer

 

 

Parameter

Sensor

Range

Resolution

Accuracy

O2

Electrochemical

0 - 25%

0.1%

±0.2% vol

CO

Electrochemical

0 - 4000 ppm

1 ppm

±5 ppm <125 ppm

±4% rdg up to 4000ppm

CO2

Calculated

0 - 99.9%

0.1%

 

T air

Pt100

-10 - 100°C

0.1°C

±0.5°C

T gas

TC K

0 - 600°C

0.1°C

±1°C

Pressure/Draft

Piezoresistive

-10hPa to 100hPa

0.01 hPa

±1% rdg.

Excess air

Calculated

1.00 - infinity

0.01

 

Efficiency

Calculated

1 - 99.9%

0.1%