| General |
| Link select single output transmitter unit Integrated air purge modules Simple maintenance design Ideal for boiler & bag house control system integration |
| |
| Specifications: |
| OPAL 100 - Control Unit |
| Enclosure | IP65 weatherproof |
| Weight | 0.8 Kg |
| Ambient Temperature | -10 to +50 Deg C |
| Power Supply | 120 or 240vac, 50/60Hz, 125vA (specify on order) |
| Connection | 5 pin quick connector (female) on 1.0 metre flying lead – to transceiver. Mains – 240vac 50 / 60Hz |
| Output | Re-transmitted 4-20mA signal via terminal connections via customer supplied output cable. Link select 1. OPACITY: 4-20mA = 0 – 100% Link select 2. OPTICAL DENSITY: 4-20mA = 0 – 0.6 |
| Optical Sensors |
| Enclosure | IP65 weatherproof |
| Weight | 3.5Kg transceiver, 1.2Kg retroreflector |
| Installation | Via 65NB stub flanges. (4 x 18mm holes on 127 pcd and 75mm bore) |
| Connection | 5 pin quick connector (male) to flying lead on OPAL 100T junction box. (Option steel flex conduit cable to Junction box – max 20 metres)) |
| Path Length | 300mm to 3600mm |
| Optical System | Double Pass system using high power LED light source with electronic light modulation |
| Lens Protection | Optional air purge fittings for either air blower or plant instrument air. |
| Process Temperature | Up to 400 Deg C standard |
| Ambient Light Immunity | Nil effect from sunlight or artificial light sources. |
| Spectral Response | 515 to 585 nm, less than 10% of peak response outside 400 to 700 nm . |
| Angle of View | <4.0° from optical axis |
| Angle of Projection | <4.0° from optical axis |
| Response Time | < 2 seconds, to 90% of actual value |
| Zero Calibration | via transceiver control pad – set clean stack conditions and press WHITE button |
| Span Calibration | via transceiver control pad – set blocked stack conditions and press BLACK button. |
| Maximum cable length | 100 metres |
| Control Features | 4-20mA signal testing sockets at stack location, push button calibration procedure, |
| Output selection | Via transceiver link selection: 1. Transmittance 0 – 100% (fixed range) 2. Opacity 0 – 100% (fixed range) 3. Optical Density 0 - 0.6 (fixed range) |