Process Oxygen Analysers-GP900

Programmable Gas Analyser

( Dwyer )

General

The Model 542 is a versatile, programmable gas analyser, based on the principles of thermal conductivity, capable of measuring almost any combination of gases. The instrument is especially suitable for measurements of mixtures containing hydrogen or helium. With the use of sensitive control systems, the thermal conductivity analyser can detect gases down to parts per million levels and up to full concentration. The analyser is pre-programmed for a wide range of sample and reference gases, easily selectable from the simple front panel menu. Calibration settings, for each combination of gases used, are stored in an internal memory and are recalled automatically every time a particular gas mix is required. This enables quick and easy switching between gas combinations. Sophisticated microprocessor electronics enable the fastest possible response time, excellent stability and flexibility. Sample pressure and flow are internally controlled allowing connection to a wide range of pressurised samples. Options include automatic calibration, when the instrument can be set to perform a zero and span calibration at timed intervals. 

Features

Programmable for different gases

Built-in linearisation

Fast response

Good stability

Insensitive to sample flow

Computer communications

Autoranging electronics

 

Applications

Gas mixing

Welding gases

Heat treatment atmospheres

Hydrogen/helium purity

Food packaging gases

 

 

Technical Specification

Ranges

Dependent on selected gas mix

Adjustable, auto-ranging

Typical: 0-1000ppm (H2 in N2) 98-100% (O2 in Ar)

Resolution

0.5% or better

Accuracy

±2% of range

Response time

90% of reading in 20 seconds

Calibration range

0-100% of selected measure gas

Automatic timed calibration as standard

Auto zero

Measuring cell type

Thermal conductivity/katherometer, ultra stable

Operating Conditions

Sample inlet pressure

1.0 to 7.0 Barg

Sample flow rate

Internally controlled (max 250ml/min)

Sample temperature

-10 to 40°C

Ambient temperature

-5 to 50°C

Sample connections

1/8" OD compression fittings (others on request)

Unsuitable gases

Corrosive gases (contact Systech for alternatives)

Power Requirements

Power supply

230/115V ±10%, 50/60Hz at 40VA

Display type

4 digit high visibility LED and 12 digit alphanumeric

Cabinetry And Mounting

Enclosure

Sheet steel

Installation

Bench or panel mounting

Dimensions

535W ~ 165H ~ 300D (mm)

Panel cutout

445W ~ 132.5D (mm), if required

Weight

12kg

Ingress protection

IP40

Options

Alarms

Two adjustable alarms with volt-free, change-over contacts

Fully configurable over complete range.

Contact rating 10A@ 240V ac/30V dc

Analogue output

0-10V, 4-20mA (0-20mA) isolated

Max loop resistance 500 Ohms

Serial interface

Allows connection to a computer

Multipoint sampling

Sequenced sampling for up to 8 sample lines

Sample gas pump

Externally mounted

IP55 enclosure

Sealed reference gas

Dependent on application and range (contact Systech for options)

Corrosive gases

Contact Systech for information on alternative options