Portable Oxygen Analyser

( Dwyer )

General

The EC92DIS portable oxygen analyser will detect levels of oxygen as low as 1ppm, up to high percent levels and can be used on most industrial gases and atmospheres. There is no need for routine maintenance of the fuel cell, and the instrument may be easily calibrated, using ambient air or standard calibration samples. The innovative design of the fast purge/cell seal system means readings of single digit parts per million oxygen can be obtained within a few minutes. Apart from a single switch, no adjustments or controls are necessary, making the unit ideal for use by non-technical personnel. Operation of the EC92DIS is made easy by the internal sample system. Taking gas measurements is simply a matter of connecting the gas line, purging for a short time and switching a valve position. When not in use the cell is sealed. The digital display is easily visible in sunlight or low level light; can display readings below 1 part per million and indicate low battery power. A calibration adjustment on the front panel can be set to give a reading of 20.9% when the analyser is working on clean air. Using this method ensures that the instrument will be absolutely accurate on any selected part of its operational range. If calibration of trace levels is required, certified calibration gas may be used.

Features
Maintenance-free sampling cell

Air calibration facility

Selectable ranges % and ppm

Powered by 2 x PP3 batteries

Certified to EEx ia IIC T4

Applications

Offshore

Gas purity checking

Inert atmospheres and cylinder gas analysis in hazardous areas

Hydrogen plants

Chemical plants

Pharmaceutical plants

Oil refineries

Petrochemical

Centrifuges


Technical Specification

Ranges

0-30% plus 3 selectable from

0-20, 0-200, 0-2000 (ppm)

0-2%, 0-20%

Resolution

0.05% of scale

Accuracy

>10ppm ±2% of reading at 20°C

±5% of reading over temperature range

<10ppm ±2% of reading + 0.4ppm at 20°C

±5% of reading + 0.4ppm + 0.15ppm/°C

over temperature range

Response time

90% of reading within 20 seconds

Calibration range

Ambient (20.9%) or certified gas

Measuring cell type

Electrochemical fuel cell

Operating Conditions

Sample inlet pressure

1.0 to 10 Barg

Sample flow rate

Internally regulated to 150ml/min

Sample temperature

0 to 40°C

Ambient temperature

0 to 40°C, RH 0-99% non-condensing

Sample connections

1/8" OD compression fitting

Unsuitable gases

Corrosives, acid gases and solvents

Power Requirements

Power supply

2 ~ PP3 dry batteries, fitted internally

Battery life

36 hours, normal life

Battery low indication

Automatic warning

Display type

Digital LCD meter

Cabinetry And Mounting

Enclosure

Sheet metal/cast aluminium

Installation

Free standing for desk, shelf or panel mounting

Dimensions

257W ~ 102H ~ 262D (mm)

Panel cutout

240W ~ 99D (mm), if required

Weight

3kg

Ingress protection

IP40

Certification

EC92DIS approved to ATEX

Approved for EEx ia IIC T4.

Certificate number Baseefa 04ATEX0258X

Options

Carrying case

Remote probe