PDFPrintE-mail
Dwyer Digital Calibration Gauge-DCGDwyer Digital Pressure Gauge DPG100

Dwyer Digital Pressure Gauge DPG

( Dwyer )

 

 

SPECIFICATIONS:

Service

Liquids and compatible gases.

Wetted Materials

Type 316L SS.

Housing Material

Black Polycarbonate front & back cover, anodized

aluminium extruded housing with recessed grooves, Polycarbonate

Overlay, Buna-N O-Rings, 316L SS Sensor Construction.

Accuracy

0.50% F.S. +/- 1 least significant digit 32 to 130°F (0 to 55°C). (Includes linearity, hysteresis, repeatability) ±2% F.S. @ 10°F. ±5%

F.S. @ 0°F.

Stability:

< ±1% per year

Pressure Limits

2x pressure range for models ≤1000 psi; 5000 psi for 3000 psi range; 7500 psi for 5000 psi range

Enclosure Rating:

Designed to meet NEMA 4/4X (IP65).

Temperature Limits

0 to 130°F (-18 to 55°C).

Thermal Effects

Between 70 to 130°F is 0.016%/F.

Between 32 to 70°F is 0.026%/F.

Between 10 to 32°F is 0.09%/F.

Between 0 to 10°F is 0.50%/F.

Size

3.00˝ OD x 1.90 Deep (max).

Process Connection

1/4˝ male NPT.

Weight

8.84 oz (275 g).

Display

4 digit (.425 H x .234 W digits).

Power Requirements

Two AAA batteries.

Battery Life

2000 hours typical; Low battery indicator.

Auto Shut-Off

Gage: 60 minute auto shut off. Auto shut-off may be disengaged.

Backlight: 2 minute auto shut-off.